|
Safety Acceptance Letter B-202
1200 New Jersey Ave. S.E. In Reply Refer to: HSSD/B-202 Dr. Ronald K. Faller Dear Dr. Faller: This letter is in response to your request for the Federal Highway Administration (FHWA) acceptance of a roadside safety system for use on the National Highway System (NHS). Name of system: TL-2 Rough Stone Masonry Guardwall You requested that we find this system acceptable for use on the NHS under the provisions of the National Cooperative Highway Research Program (NCHRP) Report 350 “Recommended Procedures for the Safety Performance Evaluation of Highway Features.” Requirements Description The reinforced concrete foundation slab is 9 inches thick and is laid on top of a 6-inch thick compacted crushed aggregate base. The top of the slab is positioned 6 inches below the traveled way. In the slab both bent and straight bars are used, as shown in Enclosure 1. A reinforced concrete core wall is constructed on top of the foundation slab. The core wall is rigidly attached to the slab using the vertical steel reinforcing bars which extended out of the slab. Weep holes are placed transversely through the parapet as shown in drawing RSMG-1v15, sheet 14 of 15, of Enclosure 1. The 7 inch thick rough stone material is attached to the inner core wall using: (1) a mortar bed on the front and top faces of the inner core wall as well as a narrow region on the surface of the slab foundation; (2) Dovetail Anchor Slots with Dovetail Anchor ties on the front surface of the core wall; (3) Dovetail Anchor Ties wedged under the steel angles that are anchored to the top surface of the core wall; (4) stainless steel, Z-clips attached to the top surface of the core wall using masonry anchors; and (5) ASTM A36 steel angles attached to the top surface of the core wall using Wedge-bolt Screw Anchors with the upper angle leg extending into kerf cut into the bottom side of the top capstone with the void space filled with mortar. The nominal top of the guardwall is 22 inches from the traveled way. Enclosure 1 illustrates the design details and general layout of the rough stone masonry guardwall. The above description is associated with the single-face rough stone masonry guardwall. Enclosure 2 shows design details and general layout of double-face rough stone masonry guardwall. The double-face rough stone masonry guardwall is structurally similar to the single-face guardwall (which was described above) but the stones are attached to both sides of the core wall. This type of wall is used where aesthetic appearance is deemed necessary for both sides of the wall (e.g. median). Crash Testing Findings The 20 inch rough stone masonry guardwall was also crash tested according to Test 2-11 and the test article successfully passed the test as can be seen in the summary sheet shown in Enclosure 5. However, black contact marks and scratches on the vertical face of the guardwall found in the post-crash investigation of the second test revealed that the guardwall was overridden by the test vehicle. Consequently, the rough stone masonry guardwall system is to be implemented with a nominal top mounting height of 22 inch relative to the traveled way. This configuration allows for a construction/operational height reduction tolerance of 2 inches. The second test shows that the rough stone masonry guardwall system described in this letter cannot be used where the nominal height of the parapet relative to the traveled way is less than 20 inches. Test 2-10 involves an 820 kg small passenger car impacting the barrier at a speed of 70 km/h and at an angle of 25 degrees. Based on previous crash tests successfully conducted on similar barriers with a small car, we concur with the University of Nebraska Researchers that Test 2-10 is not critical and the completion of the test is not necessary if the wall is constructed vertically according to the enclosed design drawings. Regarding the texture of the rough stone masonry surface, the masonry wall can have the maximum projections up to 38 mm beyond the neat line, 50 mm deep raked joints, and beds 50 -75 mm thick. These constraints are imposed according to Stone Masonry Guardwall-Design and Construction Notes for Aesthetic Barriers dated May 15, 2002, (http://www.efl.fhwa.dot.gov/files/technology/abs/StoneMasonry/design-notes/stone_descon.pdf) in order to prevent snagging of vehicles and/or excessive occupant compartment intrusion. In your letter you also requested acceptance for the double-face rough stone masonry guardwall. Your request is acceptable on the grounds that a layer of rock attached to the other side of the core wall does not degrade the performance of the system. Therefore, the system described above and detailed in the enclosed drawings is acceptable for use on the NHS under the range of conditions tested, when such use is acceptable to a highway agency. Please note the following standard provisions that apply to FHWA letters of acceptance:
5 Enclosures |
Program ContactCathy Satterfield What's NewFHWA Resource Charts, July 2013 NEW! FHWA Roadway Lighting Handbook, August 2012 NEW! RwD Strategic Plan, April 2013 NEW! Updated Guidance on Sign Retroreflectivity, April 2013 NEW! Clarifying Guidance on Daytime Luminance, January 2013 NEW! Guidance for the Selection , Use and Maintenance of Cable Barrier Systems, November 2012 NEW! |