Browse Barrier Hardware Systems

Click on a column heading to arrange the list in order of that barrier hardware system characteristic.

SYSTEM NOMENCLATURE
Valid system designators are shown in the table below. Designators are composed of three upper-case letters, two digits and an optional lower-case letter. All system designators begin with the letter S. The second letter identifies the function of the barrier, such as a guardrail (SGR03a) or a crash cushion (SCI10). The third letter identifies a type or family of similar barriers. For example, the designator SGR04b identifies a barrier system (SGR04b) which is a guardrail (SGR04b) used in roadside (SGR04b) applications. The numerical sequence for guardrails and median barriers corresponds to the 1977 AASHTO Barrier Guide designation if one exists. For example, the SGR01a is a G1 cable guardrail and SGM04a is an M4(1S). The designations in the 1977 guide progress from more flexible barriers to stiffer barriers, and this convention has been retained where possible. For most barrier systems, the optional lower case letter identifies particular variations. For example, the SGR04b is an AASHTO G4 W-beam guardrail (SGR04b), in particular the timber strong-post W-beam G4(2W) guardrail (SGR04b).

Name / Designator Image General System Type Specific System Type Test Specification Test Level Rail Type Height Aesthetic Manufacturer Review Status
SCI06b
Fitch Universal Module
No Image Crash Cushion  Independent  Report 350  TL-3  Multiple  Multiple  No  Energy Absorption Systems  No Drawing 
SCI06c
Energite III
No Image Crash Cushion  Independent  Report 350  TL-3  Multiple  Multiple  No  Energy Absorption Systems  Review Complete 
SCI07
Connecticut Impact Attenuation System
No image. Crash Cushion  Independent  Report 350  TL-3  Multiple  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SCI08
Narrow Connecticut Impact Attenuation System
No image. Crash Cushion  Independent  Report 350  TL-3  Multiple  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SCI09
ADIEM Energy Absorbing End Treatment
No image. Crash Cushion  Independent  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Trinity Highway Products  No Drawing 
SCI10
N-E-A-T System
No Image Crash Cushion  Independent  Report 350  TL-2  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Energy Absorption Systems  Review Complete 
SCI11a
ABSORB 350
No Image Crash Cushion  Independent  Report 350  TL-2  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Barrier Systems  Review Complete 
SCI11b
ABSORB 350
No Image Crash Cushion  Independent  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Barrier Systems  Review Complete 
SCI12
BEAT-BP
No Image Crash Cushion  Independent  Report 350  TL-3  Box Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SCI13a
BEAT-SSCC, Driven Posts
No Image Crash Cushion  Independent  Report 350  TL-3  Box Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SCI13b
BEAT-SSCC, Surface-Mounted Posts
No Image Crash Cushion  Independent  Report 350  TL-3  Box Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SCI14
CushionWall II
No Image Crash Cushion  Independent      Multiple    No  Energy Absorption Systems  No Drawing 
SCI15
EASI-Cell Cluster
No Image Crash Cushion  Independent  Report 350  TL-1  Multiple  H > 33 [838mm]  No  Energy Absorption Systems  Review Complete 
SCI16a
REACT 350
No Image Crash Cushion  Independent  Report 350  TL-3  Multiple  H > 33 [838mm]  No  Energy Absorption Systems  Review Complete 
SCI16b
REACT 350 (Wide)
No Image Crash Cushion  Independent  Report 350  TL-3  Multiple  H > 33 [838mm]  No  Energy Absorption Systems  Review Complete 
SCI16c
REACT 350 II
No image. Crash Cushion  Independent  Report 350  TL-3  Multiple    No  Energy Absorption Systems  No Drawing 
SCI17a
SCI100GM Impact Attenuator
No Image Crash Cushion  Independent  Report 350  TL-3  Multiple  30 [762mm] < H ≤ 33 [838mm]  No  Work Area Protection Corp.  Review Complete 
SCI17b
SCI70GM Impact Attenuator
No Image Crash Cushion  Independent  Report 350  TL-2  Multiple  30 [762mm] < H ≤ 33 [838mm]  No  Work Area Protection Corp.  Review Complete 
SCI17d
SCI SmartCushion SCI100GM Impact Attenuator, MASH TL-3
No image. Crash Cushion  Independent  MASH  TL-3  Multiple  30 [762mm] < H ≤ 33 [838mm]  No  Work Area Protection Corp.  In Review 
SCI18a
TRACC Crash Cushion Family (Narrow)
No image. Crash Cushion  Independent  Report 350  TL-3  Multiple    No  Trinity Highway Products  No Drawing 
SCI18b
TRACC Crash Cushion Family
No image. Crash Cushion  Independent  Report 350  TL-3  Multiple    No  Trinity Highway Products  No Drawing 
SCI19
Stop Gate
No Image Crash Cushion  Independent  Report 350  TL-2  Multiple    No  Energy Absorption Systems  No Drawing 
SCI20
Quest Crash Cushion
No image. Crash Cushion  Independent  Report 350  TL-3  Multiple    No  Energy Absorption Systems  No Drawing 
SCI21
HEART Crash Cushion
No image. Crash Cushion  Independent  Report 350  TL-3  Multiple    No  Trinity Highway Products  No Drawing 
SCI22a
SLED Sentry Longitudinal Energy Dissipater
No image. Crash Cushion  Independent  Report 350  TL-2  Multiple    No  Traffix Devices, Inc.  No Drawing 
SCI22b
MASH Sentry Longitudinal Energy Dissipater (SLED)
No image. Crash Cushion  Independent  MASH  TL-3  Multiple    No  Traffix Devices, Inc.  No Drawing 
SCI23
X-Tenuator Crash Cushion
No image. Crash Cushion  Independent  Report 350  TL-3  Multiple  30 [762mm] < H ≤ 33 [838mm]  No  Barrier Systems  Review Complete 
SCI24
ACZ 350 TL-2 Crash Cushion
No image. Crash Cushion  Independent  Report 350  TL-2  Multiple    No  Energy Absorption Systems  No Drawing 
SCI25
Raptor Crash Cushion TL-1
No Image Crash Cushion  Independent  Report 350  TL-1  Multiple  H > 33 [838mm]  No  Barrier Systems  No Drawing 
SCI26a
Quadguard M10 Narrow Family
No image. Crash Cushion  Independent  MASH  TL-3  Multiple    No  Energy Absorption Systems  No Drawing 
SCI26b
Quadguard M10 Narrow Family
No image. Crash Cushion  Independent  MASH  TL-3  Multiple    No  Energy Absorption Systems  No Drawing 
SCI27
Quadguard M10 Wide Family
No image. Crash Cushion  Independent  MASH  TL-3  Multiple    No  Energy Absorption Systems  No Drawing 
SCI28
Compressor Crash Cushion
No image. Crash Cushion  Independent  Report 350  TL-3  Multiple    No  Traffix Devices, Inc.  No Drawing 
SCI29
ArmorZone End Terminal TL-2
No Image Crash Cushion  Independent  Report 350  TL-2  Multiple  H > 33 [838mm]  No  Barrier Systems  Review Complete 
SCI30
Quadguard M10 Narrow Family TL-2
No image. Crash Cushion  Independent  MASH  TL-2  Multiple    No  Energy Absorption Systems  No Drawing 
SCI31
Quadguard M10 Wide Family TL-2
No image. Crash Cushion  Independent  MASH  TL-2  Multiple    No  Energy Absorption Systems  No Drawing 
SCI32
CrashGard Sand Barrel System
No Image Crash Cushion  Independent  Report 350  TL-3  Multiple    No  Plastic Safety Systems, Inc.  No Drawing 
SCI33
QuadGuard Elite 8 Bay M10
No image. Crash Cushion  Independent  MASH  TL-3  Multiple    No  Energy Absorption Systems  No Drawing 
SCI34
QuadGuard Elite 8 Bay Wide M10
No image. Crash Cushion  Independent  MASH  TL-3  Multiple    No  Energy Absorption Systems  No Drawing 
SCI35
QuadGuard Elite 4 Bay M10
No image. Crash Cushion  Independent  MASH  TL-2  Multiple    No  Energy Absorption Systems  No Drawing 
SCI36
QuadGuard Elite 4 Bay Wide M10
No image. Crash Cushion  Independent  MASH  TL-2  Multiple    No  Energy Absorption Systems  No Drawing 
SCT01a
Universal TAU II
No Image Crash Cushion  Thrie-beam  Report 350  TL-2  Multiple    No  Barrier Systems  Review Complete 
SCT01b
Universal TAU-II
No Image Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Barrier Systems  Review Complete 
SCT01c
Universal TAU-II-R
No Image Crash Cushion  Thrie-beam  Report 350  TL-2  Multiple    No  Barrier Systems  Review Complete 
SCT01d
Universal TAU-II-R
No Image Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Barrier Systems  Review Complete 
SCT02a
Quadguard System 24, 30, or 36 wide
No Image Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Energy Absorption Systems  Review Complete 
SCT02b
Quadguard CZ System
No Image Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Energy Absorption Systems  Review Complete 
SCT02c
Quadguard CZ System on a Plate
No Image Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Energy Absorption Systems  Review Complete 
SCT02d
QuadGuard High Speed
No Image Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Energy Absorption Systems  Review Complete 
SCT02e
QuadGuard Elite System
No Image Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Energy Absorption Systems  Review Complete 
SCT02f
QuadGuard LMC System
No Image Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Energy Absorption Systems  Review Complete 
SCT02g
QuadGuard 10 Degree Flare
No image. Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Energy Absorption Systems  No Drawing 
SCT02h
QuadGuard System (69 or 90 wide)
No image. Crash Cushion  Thrie-beam  Report 350  TL-3  Multiple    No  Energy Absorption Systems  Review Complete 
SEB01
Box-Beam Guardrail Anchor
No image. End Treatment / Terminal / Anchor  Box  MASH  TL-3  Box Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  No Drawing 
SEB03
WY-BET Wyoming Box Beam End Terminal
No image. End Treatment / Terminal / Anchor  Box  Report 350  TL-3  Box Beam    No  Trinity Highway Products  No Drawing 
SEB04
WY-BET Wyoming Box Beam End Terminal (Median)
No image. End Treatment / Terminal / Anchor  Box  Report 350  TL-3  Box Beam    No  Trinity Highway Products  No Drawing 
SEB05
Box Beam BEAT
No Image End Treatment / Terminal / Anchor  Box  Report 350  TL-3  Box Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SEB06
Box Beam BEAT-MT (Median)
No Image End Treatment / Terminal / Anchor  Box  Report 350  TL-3  Box Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SEC01
Cable Guardrail Anchor
No image. End Treatment / Terminal / Anchor  Cable  Report 350  TL-3  Cable  26 [660mm] < H ≤ 30 [762mm]  Yes  Non-Proprietary  Review Complete 
SEC07b
Brifen Wire Rope End Treatment
No image. End Treatment / Terminal / Anchor  Cable  Report 350  TL-3  Cable    Yes  Brifen USA  No Drawing 
SEC07e
NUCOR Cable End Terminal
No image. End Treatment / Terminal / Anchor  Cable  Report 350  TL-3  Cable  Multiple  Yes  Nucor Steel Marion, Inc.  No Drawing 
SEC08
ArmorWire End Terminal TL-3
No Image End Treatment / Terminal / Anchor  Cable  Report 350  TL-3  Cable    Yes  Armorflex International  No Drawing 
SEC09
Safence Cable End Terminal
No image. End Treatment / Terminal / Anchor  Cable  Report 350  TL-3  Cable    Yes  Gregory Corp.  No Drawing 
SEC10
Cable End Terminal Low Tension
No image. End Treatment / Terminal / Anchor  Cable  Report 350  TL-3  Cable    Yes  Non-Proprietary  No Drawing 
SED01
Steel Backed Timber Guardrail Tangent End Terminal
No image. End Treatment / Terminal / Anchor    Report 350  TL-2  Wood/Steel    Yes  Non-Proprietary  No Drawing 
SER01
Low-Profile Construction-Zone End Treatment
No image. End Treatment / Terminal / Anchor  Rigid  Report 350  TL-2  Other  H ≤ 26 [660mm]  No  Non-Proprietary  No Drawing 
SER02a
Triton Barrier Concrete End Treatment
No Image End Treatment / Terminal / Anchor  Rigid  Report 350  TL-2  Closed Profile    No  Energy Absorption Systems  Review Complete 
SER02b
Triton Barrier Concrete End Treatment
No Image End Treatment / Terminal / Anchor  Rigid  Report 350  TL-3  Closed Profile    No  Energy Absorption Systems  Review Complete 
SER03
Low-Profile Concrete Barrier End Treatment
No image. End Treatment / Terminal / Anchor  Rigid  Report 350  TL-2  Closed Profile  H ≤ 26 [660mm]  No  Non-Proprietary  Review Complete 
SER04
Florida Low-Profile Barrier Terminal
No image. End Treatment / Terminal / Anchor  Rigid  Report 350  TL-2  Closed Profile  H ≤ 26 [660mm]  No  Non-Proprietary  In Review 
SET02
Quadtrend 350
No Image End Treatment / Terminal / Anchor  Thrie-beam  Report 350  TL-3  Thrie-beam    No  Energy Absorption Systems  Review Complete 
SET03a
Thrie Beam Bull Nose, Wood Post
No Image End Treatment / Terminal / Anchor  Thrie-beam  Report 350  TL-3  Thrie-beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SET03b
Thrie Beam Bull Nose, Steel Post
No image. End Treatment / Terminal / Anchor  Thrie-beam  Report 350  TL-3  Thrie-beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SEW06
Brakemaster 350
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Energy Absorption Systems  Review Complete 
SEW08
C-A-T Crash-Cushion/Attenuating Terminal
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam    No  Trinity Highway Products  No Drawing 
SEW12
Slotted Rail Terminal (SRT)
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam    No  Trinity Highway Products  No Drawing 
SEW12c
Slotted Rail Terminal (SRT) MASH
No image. End Treatment / Terminal / Anchor  W-beam  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Trinity Highway Products  No Drawing 
SEW14a
FLEAT
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SEW14b
FLEAT
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-2  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SEW15
FLEAT - MGS System
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Road Systems, Inc.  Review Complete 
SEW16a
FLEAT-MT Median Terminal
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SEW16b
FLEAT-MT Median Terminal for MGS
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam    No  Road Systems, Inc.  No Drawing 
SEW17a
Sequential Kinking Terminal (SKT)
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SEW17b
Sequential Kinking Terminal (SKT) Lite
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SEW17c
Sequential Kinking Terminal (SKT)
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-2  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Road Systems, Inc.  Review Complete 
SEW17d
MASH Sequentially Kinking Terminal (MSKT)
No image. End Treatment / Terminal / Anchor  W-beam  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Road Systems, Inc.  No Drawing 
SEW18a
Sequential Kinking Terminal (SKT) - MGS
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Road Systems, Inc.  Review Complete 
SEW18b
Sequential Kinking Terminal (SKT) - MGS Lite
No Image End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Road Systems, Inc.  Review Complete 
SEW19
X-TENSION Guardrail Terminal, Tangent
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Barrier Systems  In Review 
SEW20
X-TENSION Guardrail Terminal, Flared
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Barrier Systems  In Review 
SEW21
X-TENSION Median Guardrail Terminal (XMAS )
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Barrier Systems  In Review 
SEW22a
Soft Stop End Terminal, TL-3
No image. End Treatment / Terminal / Anchor  W-beam  MASH  TL-3  W-Beam    No  Trinity Highway Products  No Drawing 
SEW22b
Soft Stop End Terminal, TL-2
No image. End Treatment / Terminal / Anchor  W-beam  MASH  TL-2  W-Beam    No  Trinity Highway Products  No Drawing 
SEW22c
Soft Stop End Terminal, TL-1
No image. End Treatment / Terminal / Anchor  W-beam  MASH  TL-1  W-Beam    No  Trinity Highway Products  No Drawing 
SEW23
X-LITE System, Tangent
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  Multiple  No  Barrier Systems  In Review 
SEW24
X-LITE System, Flared
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam  Multiple  No  Barrier Systems  In Review 
SEW25a
TREND End Terminal, Tangent
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam    No  Energy Absorption Systems  No Drawing 
SEW25b
TREND End Terminal, Flared
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam    No  Energy Absorption Systems  No Drawing 
SEW26
TREND End Terminal, Median
No image. End Treatment / Terminal / Anchor  W-beam  Report 350  TL-3  W-Beam    No  Energy Absorption Systems  No Drawing 
SEW31
Trailing-End Anchorage for 31" Guardrail
No image. End Treatment / Terminal / Anchor  W-beam  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  No Drawing 
SGM01a
Weak-Steel Post Cable Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Cable  26 [660mm] < H ≤ 30 [762mm]  Yes  Non-Proprietary  Review Complete 
SGM01b
Weak-Steel Post High Tension Cable Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Cable    Yes  Non-Proprietary  No Drawing 
SGM02
Weak-Post W-Beam Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-2  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM03
Weak-Post Box-Beam Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Box Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGM04a
Strong Post W-Beam Median Barrier, Steel Posts, Wood or Composite Blockouts
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGM04b
Strong Post W-Beam Median Barrier, Wood Posts, Wood or Composite Blockouts
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGM06a
Strong-Post W-Beam Median Barrier with Rub Rail, Steel Post
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM06b
Strong-Post W-Beam Median Barrier with Rub Rail, Wood Post
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM07a
Gibraltar TL-3 Cable Barrier
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Cable  Multiple  Yes  Gibraltar  No Drawing 
SGM07b
Gibraltar TL-4 Cable Barrier
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Cable  Multiple  Yes  Gibraltar  No Drawing 
SGM07e
NU-CABLE TL-3 Median
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Cable  Multiple  Yes  Nucor Steel Marion, Inc.  In Review 
SGM07f
NU-CABLE TL-4 Median
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Cable  Multiple  Yes  Nucor Steel Marion, Inc.  In Review 
SGM09a
Thrie-Beam Median Barrier, Steel Posts, Wood or Composite Blockouts
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Thrie-beam  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM09b
Modified Thrie-Beam Median Barrier, Steel Posts, Steel Blockouts
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Thrie-beam  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM09c
Thrie-Beam Median Barrier, Wood Posts, Wood or Composite Blockouts
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Thrie-beam  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM10a
F-Shape Median Barrier
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM10b
F-Shape Median Barrier
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-5  Closed Profile  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM11a
Safety-Shape Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM11b
Safety-Shape Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-5  Closed Profile  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM12
Tall-Wall Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-5  Closed Profile  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM13
3N Median Barrier
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-5  Thrie-beam  H > 33 [838mm]  No  Fracasso, S.p.A.  No Drawing 
SGM14
Constant Slope Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-5  Closed Profile  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM15a
Visi-Barrier 32" F-Shape Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Transpo Industries, Inc.  In Review 
SGM15b
Visi-Barrier 42" F-Shape Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-5  Closed Profile  H > 33 [838mm]  No  Transpo Industries, Inc.  In Review 
SGM15c
Visi-Barrier 32" Safety Shape Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Transpo Industries, Inc.  In Review 
SGM15d
Visi-Barrier 42" Safety Shape Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-5  Closed Profile  H > 33 [838mm]  No  Transpo Industries, Inc.  In Review 
SGM15e
Visi-Barrier 32" Single-Slope Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Transpo Industries, Inc.  In Review 
SGM15f
Visi-Barrier 42" Single-Slope Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-5  Closed Profile  H > 33 [838mm]  No  Transpo Industries, Inc.  In Review 
SGM20
Barriergate
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Closed Profile    No  Energy Absorption Systems  Review Complete 
SGM22a
Reactive Tension Movable Barrier, TL-3
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Barrier Systems  In Review 
SGM22b
Reactive Tension Movable Barrier, TL-4
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Closed Profile    No  Barrier Systems  In Review 
SGM23
Armorguard Gate
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Closed Profile    No  Barrier Systems  In Review 
SGM24
NU-GUARD-27 Median Barrier
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Nucor Steel Marion, Inc.  In Review 
SGM25a
NU-GUARD-31 Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Nucor Steel Marion, Inc.  In Review 
SGM25b
NU-GUARD-31 Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Nucor Steel Marion, Inc.  In Review 
SGM25c
NU-GUARD-31 Median Barrier
No Image Guardrail / Median Barrier  Median Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Nucor Steel Marion, Inc.  In Review 
SGM26a
GMS Guardrail: 27" Median W-Beam, 150" Post Spacing
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Gregory Corp.  In Review 
SGM26b
GMS Guardrail: 27" Median W-Beam, 75" Post Spacing
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Gregory Corp.  In Review 
SGM26c
GMS Guardrail: 27" Median W-Beam, 37-1/2" Post Spacing
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Gregory Corp.  In Review 
SGM26d
GMS Guardrail: 27" Median W-Beam, 18-3/4" Post Spacing
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Gregory Corp.  In Review 
SGM27a
GMS Guardrail: 31" Median W-Beam, 150" Post Spacing
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Gregory Corp.  In Review 
SGM27b
GMS Guardrail: 31" Median W-Beam, 75" Post Spacing
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Gregory Corp.  In Review 
SGM27c
GMS Guardrail: 31" Median W-Beam, 37-1/2" Post Spacing
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Gregory Corp.  In Review 
SGM27d
GMS Guardrail: 31" Median W-Beam, 18-3/4" Post Spacing
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Gregory Corp.  In Review 
SGM28
SAFENCE Cable Median Barrier
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Cable    Yes  Gregory Corp.  No Drawing 
SGM29
Midwest Guardrail System, MGS Median Barrier
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGM30
VarioGuard C Freestanding Barrier
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Other  H > 33 [838mm]  No  Volkmann and Rossbach  No Drawing 
SGM31
Emergency Median Access Barrier
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  Closed Profile    No  Cumberland Barrier, Inc.  No Drawing 
SGM32
SAFENCE Cable Barrier on 4H:1V Slopes
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  Cable    Yes  Gregory Corp.  No Drawing 
SGM33a
ArmorWire Cable Barrier TL-3
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Cable  30 [762mm] < H ≤ 33 [838mm]  Yes  Armorflex International  In Review 
SGM33b
ArmorWire Cable Barrier TL-4
No Image Guardrail / Median Barrier  Median Barrier  Report 350  TL-4  Cable  30 [762mm] < H ≤ 33 [838mm]  Yes  Armorflex International  In Review 
SGM34
Rough Stone Masonry Guardrail TL-2
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-2  Closed Profile  H ≤ 26 [660mm]  Yes  Non-Proprietary  Review Complete 
SGM35
GMS GUARDRAIL: 39" MEDIAN THRIE-BEAM
No image. Guardrail / Median Barrier  Median Barrier  Report 350  TL-3  Thrie-beam  H > 33 [838mm]  No  Gregory Corp.  In Review 
SGM36a
CASS System S3 Post, 4H:1V Slopes, TL-3
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  Cable    Yes  Trinity Highway Products  No Drawing 
SGM36b
CASS System S3 Post, TL-4
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-4  Cable    Yes  Trinity Highway Products  No Drawing 
SGM37
Brifen Wire Rope Safety Fence O-Post
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-3  Cable    Yes  Brifen USA  No Drawing 
SGM41
KSI Global Safety Roller Median Barrier
No image. Guardrail / Median Barrier  Median Barrier  MASH  TL-4  Other  H > 33 [838mm]  No  KSI Global Australia  No Drawing 
SGR01a
Weak-Steel Post Cable Guardrail
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Cable  26 [660mm] < H ≤ 30 [762mm]  Yes  Non-Proprietary  Review Complete 
SGR01b
Weak-Steel Post Cable Guardrail
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Cable  26 [660mm] < H ≤ 30 [762mm]  Yes  Non-Proprietary  Review Complete 
SGR01d
Weak-Steel Post High Tension Cable Guardrail
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Cable    Yes  Non-Proprietary  No Drawing 
SGR02a
Weak-Post W-Beam Guardrail
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-2  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR02b
Modified Weak-Post W-Beam Guardrail
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR03
Weak-Post Box-Beam Guardrail
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Box Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR04a
Strong Post W-Beam Guardrail, Steel Posts, Steel Blockouts
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-2  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR04b
Strong Post W-Beam Guardrail, Wood Posts, Wood or Composite Blockouts
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR04c
Strong Post W-Beam Guardrail, Steel Posts, Wood or Composite Blockouts
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR05
Culvert Mounted W-Beam Guardrail
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  No Drawing 
SGR07a
Trinty CASS (Cable Safety System), TL-3
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Cable    Yes  Trinity Highway Products  No Drawing 
SGR07b
Trinity CASS (Cable Safety System), TL-4
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-4  Cable    Yes  Trinity Highway Products  No Drawing 
SGR07c
BRIFEN Wire Rope Safety Fence, TL-3
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-4  Cable    Yes  Brifen USA  No Drawing 
SGR07d
BRIFEN Wire Rope Safety Fence, TL-4
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-4  Cable    Yes  Brifen USA  No Drawing 
SGR07e
NU-CABLE TL-3 Roadside Barrier
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Cable  Multiple  Yes  Nucor Steel Marion, Inc.  In Review 
SGR07f
NU-CABLE TL-4 Roadside Barrier
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-4  Cable  Multiple  Yes  Nucor Steel Marion, Inc.  In Review 
SGR08a
Ironwood Aesthetic Guardrail
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Wood/Steel  26 [660mm] < H ≤ 30 [762mm]  Yes  West-East Partners, LLC  Review Complete 
SGR09a
Thrie-Beam Guardrail, Steel Posts, Wood or Composite Blockouts
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Thrie-beam  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR09b
Modified Thrie-Beam Guardrail, Steel Posts, Steel Blockouts
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-4  Thrie-beam  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR09c
Thrie-Beam Guardrail, Wood Posts, Wood or Composite Blockouts
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Thrie-beam  H > 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR13
3N Guardrail
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-5  Thrie-beam    No  Fracasso, S.p.A.  No Drawing 
SGR15
Safe-T-Curve Barrier
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]    Barrier Systems  Review Complete 
SGR20a
Midwest Guardrail System, Steel Post, 75" Spacing
No Image Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR20b
Midwest Guardrail System, Wood Post, 75" Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR20c
Midwest Guardrail System, White Pine Post, 75" Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR20d
Midwest Guardrail System, Southern Yellow Pine Post, 75" Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  No Drawing 
SGR21a
Midwest Guardrail System, Steel Post, 37-1/2" Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR21b
Midwest Guardrail System, Wood Post, 37-1/2" Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR22a
Midwest Guardrail System, Steel Post, 18-3/4" Spacing
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR22b
Midwest Guardrail System, Wood Post, 18-3/4" Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR23a
Midwest Guardrail System, Steel Post, 75" Spacing with Curb
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR23b
Midwest Guardrail System, Wood Post, 75" Spacing with Curb
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR24a
Strong-Post W-Beam Guardrail, Steel Post, 37-1/2" Spacing on Slope
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR24b
Strong-Post W-Beam Guardrail, Wood Post, 37-1/2" Spacing on Slope
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR25
W-Beam Guardrail, 37-1/2" Spacing on Concrete Box Culvert
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR26a
Strong-Post W-Beam Guardrail, Steel Post, Nested, with 4" Curb
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR26b
Strong-Post W-Beam Guardrail, Wood Post, Nested, with 4" Curb
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR27a
Strong Post W-Beam Guardrail, Steel Post placed in Rock
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR27b
Strong Post W-Beam Guardrail, Wood Post placed in Rock
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR28a
MGS With Round Posts, Single Blockout, Douglas Fir
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR28b
MGS With Round Posts, Single Blockout, Ponderosa Pine
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR28c
MGS With Round Posts, Single Blockout, Southern Yellow Pine
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR28d
MGS With Round Posts, Built-up Blockout, Douglas Fir
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR28e
MGS With Round Posts, Built-up Blockout, Ponderosa Pine
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR28f
MGS With Round Posts, Built-up Blockout, Southern Yellow Pine
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR29a
W-Beam, Steel Post, 25-ft Long-Span with 100-ft Nested Rail
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR29b
W-Beam, Wood Post, 25-ft Long-Span with 100-ft Nested Rail
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SGR30
Timber Guardrail System for Attachment to Noise Wall
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  Wood  26 [660mm] < H ≤ 30 [762mm]  Yes  Non-Proprietary  Review Complete 
SGR31
Low Profile Concrete Barrier
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-2  Closed Profile  H ≤ 26 [660mm]  No  Non-Proprietary  Review Complete 
SGR32
NU-GUARD-27 Roadside Barrier
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Nucor Steel Marion, Inc.  In Review 
SGR33a
NU-GUARD-31 Roadside Barrier
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Nucor Steel Marion, Inc.  In Review 
SGR33b
NU-GUARD-31 Roadside Barrier
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-4  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Nucor Steel Marion, Inc.  In Review 
SGR33c
NU-GUARD-31 Roadside Barrier
No Image Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Nucor Steel Marion, Inc.  In Review 
SGR34a
GMS Guardrail: 27" Roadside W-Beam, 150" Post Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Gregory Corp.  In Review 
SGR34b
GMS Guardrail: 27" Roadside W-Beam, 75" Post Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Gregory Corp.  In Review 
SGR34c
GMS Guardrail: 27" Roadside W-Beam, 37-1/2" Post Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Gregory Corp.  In Review 
SGR34d
GMS Guardrail: 27" Roadside W-Beam, 18-3/4" Post Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Gregory Corp.  In Review 
SGR35a
GMS Guardrail: 31" Roadside W-Beam, 150" Post Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Gregory Corp.  In Review 
SGR35b
GMS Guardrail: 31" Roadside W-Beam, 75" Post Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Gregory Corp.  In Review 
SGR35c
GMS Guardrail: 31" Roadside W-Beam, 37-1/2" Post Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Gregory Corp.  In Review 
SGR35d
GMS Guardrail: 31" Roadside W-Beam, 18-3/4" Post Spacing
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Gregory Corp.  In Review 
SGR36
Formet Srong Post Thrie Beam
No image. Guardrail / Median Barrier  Roadside Barrier      Thrie-beam    No  Formet, Inc.  No Drawing 
SGR37
Rough Stone Masonry Guardwall TL-2
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-2  Closed Profile  H ≤ 26 [660mm]  Yes  Non-Proprietary  Review Complete 
SGR38a
MGS Adjacent to 2H:1V Fill Slope, Steel Post
No Image Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  In Review 
SGR38b
MGS Adjacent to 2H:1V Fill Slope, Wood Post
No Image Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  In Review 
SGR39
Non-Blocked MGS Adjacent to 3H:1V Fill Slope on Top of Wire-Faced MSE Wall
No Image Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR40
T-Intersection, Short Radius W-Beam Guardrail System, TL-2
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-2  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  In Review 
SGR41
Midwest Guardrail System MGS, 31" Non-Blocked
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SGR42
Single-Slope Concrete Barrier Placed in Front of Steep Slope
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  In Review 
SGR43
GMS Guardrail: 39" Roadside Thrie-Beam
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  Thrie-beam  H > 33 [838mm]  No  Gregory Corp.  In Review 
SGR44
Ezy-Guard Heavy Duty W-Beam Guardrail
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  26 [660mm] < H ≤ 30 [762mm]  No  Ingal Civil Products  In Review 
SGR45
Low-Profile Reinforced Concrete Barrier, TL-2
No image. Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-2  Other  H ≤ 26 [660mm]  No  Non-Proprietary  No Drawing 
SGR46
Nature Rail Quick-Joint 2.0 Aesthetic Wood/Steel Guardrail
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-2  Wood/Steel  26 [660mm] < H ≤ 30 [762mm]  Yes  Gregory Corp.  No Drawing 
SGR47
31" W-Beam Guardrail with 8" Offset Block
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  In Review 
SGR48
Retro-Rail
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam  Multiple  No  Trinity Highway Products  No Drawing 
SGR49
Tim-Barrier StreetGuard Plus Rail System
No Image Guardrail / Median Barrier  Roadside Barrier  Report 350  TL-2  Wood/Steel  26 [660mm] < H ≤ 30 [762mm]  Yes  S. I. Storey Lumber Co., Inc.  In Review 
SGR50
Gravix Barrier/Retaining Wall System
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-4  Closed Profile  H > 33 [838mm]  No  Earth Wall Products, LLC  No Drawing 
SGR51
Non-Blocked BMS2-TL3 Single Steel Guardrail
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-3  W-Beam    No  XavierC, LLC  No Drawing 
SGR61
KSI Global Safety Roller Roadside Barrier
No image. Guardrail / Median Barrier  Roadside Barrier  MASH  TL-4  Other  H > 33 [838mm]  No  KSI Global Australia  No Drawing 
SGR62
Cement Rubble Masonry (CRM) Guardrail Wall
No image. Guardrail / Median Barrier  Miscellaneous  MASH  TL-1  Closed Profile  H ≤ 26 [660mm]  Yes  Non-Proprietary  No Drawing 
SWC01
Quickchange Moveable Barrier
No image. Work Zone  Concrete  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Barrier Systems  Review Complete 
SWC02
J-J Hooks Portable Concrete Barrier
No Image Work Zone  Concrete  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Easi-Set Industries  Review Complete 
SWC02b
J-J Hooks Bolt Down F-Shape Barrier
No image. Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Easi-Set Industries  No Drawing 
SWC02c
J-J Hooks Pin Down F-Shape Barrier
No image. Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Easi-Set Industries  No Drawing 
SWC03
Low-Profile Construction-Zone Barrier
No image. Work Zone  Concrete  Report 350  TL-2  Closed Profile  H ≤ 26 [660mm]  No  Non-Proprietary  No Drawing 
SWC04
Pin and Rebar Portable Concrete Barrier
No image. Work Zone  Concrete  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SWC08
Removable Temporary Work Zone Barrier Anchors
No image. Work Zone  Concrete      Closed Profile    No  Clamp Crete Corporation  No Drawing 
SWC09
Portable F-Shape Concrete Barrier Element
No Image Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SWC10
Tie-Down Strap System for F-Shape Concrete Barrier
No Image Work Zone  Concrete  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SWC11
Bolted-Down Temporary F-Shape Concrete Barrier
No Image Work Zone  Concrete  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SWC12
Driven Pins Through Asphalt For F-Shape Concrete Barriers
No Image Work Zone  Concrete  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SWC13
South Carolina DOT Temporary Concrete Barrier
No image. Work Zone  Concrete  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  In Review 
SWC14
Florida DOT Temporary Concrete Barrier
No image. Work Zone  Concrete  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  In Review 
SWC15
Louisiana 12-ft Pinned Temporary Concrete Barrier
No image. Work Zone  Concrete  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  No Drawing 
SWC16
Portable Concrete Median Barrier Transition
No Image Work Zone  Concrete  MASH  TL-3  Closed Profile  Multiple  No  Non-Proprietary  Review Complete 
SWC17
Portable Concrete Barrier Termination
No Image Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  Review Complete 
SWC18
Delta Bloc DB 80 F-Shape 12
No image. Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Delta Block International GmbH  No Drawing 
SWC19
Portable Concrete Barrier (PCB) Deflection-Reducing Retrofit
No image. Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Strongstown's B&K Enterprises, Inc.  No Drawing 
SWC20a
Low-Deflection Portable Concrete Barrier (PCB) Retrofit, Version 1
No image. Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  In Review 
SWC20b
Low-Deflection Portable Concrete Barrier (PCB) Retrofit, Version 2
No image. Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  In Review 
SWC21
Indiana Anchored Temporary Concrete Barrier
No image. Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Non-Proprietary  No Drawing 
SWC22
12-ft T-Lok F-Shape Portable Concrete Barrier
No image. Work Zone  Concrete  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Rockingham Precast  No Drawing 
SWM01
Triton Barrier
No image. Work Zone  Miscellaneous  Report 350  TL-2  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Energy Absorption Systems  No Drawing 
SWM02
Dragnet Vehicle Arresting Barrier
No Image Work Zone  Miscellaneous  Report 350  TL-3  Other  Multiple  No  Energy Absorption Systems  Review Complete 
SWM03a
Triton Barrier, TL-3
No Image Work Zone  Miscellaneous  Report 350  TL-3  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM03b
Triton Barrier, TL-2
No Image Work Zone  Miscellaneous  Report 350  TL-2  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM03c
Triton Barrier, TL-1
No Image Work Zone  Miscellaneous  Report 350  TL-1  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM04a
Vulcan Barrier, TL-4
No image. Work Zone  Miscellaneous  Report 350  TL-4  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM04b
Vulcan Barrier, TL-3
No image. Work Zone  Miscellaneous  Report 350  TL-3  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM04c
Vulcan Barrier, TL-2
No image. Work Zone  Miscellaneous  Report 350  TL-2  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM06
BarrierGuard 800
No Image Work Zone  Miscellaneous  Report 350  TL-4  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Barrier Systems  Review Complete 
SWM07
ArmorGuard Barrier
No Image Work Zone  Miscellaneous  Report 350  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Barrier Systems  Review Complete 
SWM08
Free Standing, H-Pile, Steel Temporary Barrier System
No Image Work Zone  Miscellaneous  Report 350  TL-3  Closed Profile  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SWM09
Bolted-Down, H-Pile, Steel Temporary Barrier System
No Image Work Zone  Miscellaneous  Report 350  TL-3  Closed Profile  26 [660mm] < H ≤ 30 [762mm]  No  Non-Proprietary  Review Complete 
SWM10a
ZoneGuard Portable Steel Barrier
No image. Work Zone  Miscellaneous  Report 350  TL-4  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Hill & Smith, Inc  In Review 
SWM10b
ZoneGuard Portable Steel Barrier
No image. Work Zone  Miscellaneous  MASH  TL-3  Closed Profile  30 [762mm] < H ≤ 33 [838mm]  No  Hill & Smith, Inc  In Review 
SWM11
YODOCK Rail Kit for Barrier Wall, TL-2
No image. Work Zone  Miscellaneous  Report 350  TL-2  Closed Profile    No  Trinity Highway Products  No Drawing 
SWM15a
Vulcan Barrier Gate, TL-2
No image. Work Zone  Miscellaneous  Report 350  TL-2  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM15b
Vulcan Barrier Gate, TL-3
No image. Work Zone  Miscellaneous  Report 350  TL-3  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM15c
Vulcan Barrier Gate, TL-4
No image. Work Zone  Miscellaneous  Report 350  TL-4  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM16
Orion Portable Steel Barrier TL-3
No Image Work Zone  Miscellaneous  Report 350  TL-3  Closed Profile  H > 33 [838mm]  No  Barrier Systems  In Review 
SWM17
ArmorZone Barrier, TL-2, MASH
No Image Work Zone  Miscellaneous  MASH  TL-2  Closed Profile  H > 33 [838mm]  No  Barrier Systems  In Review 
SWM18
TRACC/Vulcan Transition
No image. Work Zone  Miscellaneous  Report 350  TL-3  Closed Profile    No  Energy Absorption Systems  No Drawing 
SWM19
YODOCK Rail Kit for Barrier Wall, TL-3
No image. Work Zone  Miscellaneous  Report 350  TL-3  Closed Profile    No  Trinity Highway Products  No Drawing 
8981 visitors have viewed this page since June 24, 2016.