Browse Crash Cushion Systems

Click on a column heading to arrange the list in order of that crash cushion system characteristic.

SYSTEM NOMENCLATURE
Valid system designators are shown in the table below. Designators are composed of three upper-case letters, two digits and an optional lower-case letter. All system designators begin with the letter S. The second letter identifies the function of the barrier, such as a guardrail (SGR03a) or a crash cushion (SCI10). The third letter identifies a type or family of similar barriers. For example, the designator SGR04b identifies a barrier system (SGR04b) which is a guardrail (SGR04b) used in roadside (SGR04b) applications. The numerical sequence for guardrails and median barriers corresponds to the 1977 AASHTO Barrier Guide designation if one exists. For example, the SGR01a is a G1 cable guardrail and SGM04a is an M4(1S). The designations in the 1977 guide progress from more flexible barriers to stiffer barriers, and this convention has been retained where possible. For most barrier systems, the optional lower case letter identifies particular variations. For example, the SGR04b is an AASHTO G4 W-beam guardrail (SGR04b), in particular the timber strong-post W-beam G4(2W) guardrail (SGR04b).

Name / Designator Image System Type Test Specification Test Level Functional Type Permanent Application Temporary Application System Length System Width at Rear System Height Manufacturer Review Status
SCI06c
Energite III
No Image Independent (I)  Report 350  TL-3            Multiple  Energy Absorption Systems  Review Complete 
SCI08
Narrow Connecticut Impact Attenuation System
No image. Independent (I)  Report 350  TL-3            H > 33 [838mm]  Non-Proprietary  Review Complete 
SCT02c
Quadguard CZ System on a Plate
No Image Thrie-Beam (T)  Report 350  TL-3              Energy Absorption Systems  Review Complete 
SCI11b
ABSORB 350
No Image Independent (I)  Report 350  TL-3            30 [762mm] < H ≤ 33 [838mm]  Barrier Systems by Lindsay  Review Complete 
SCT01b
Universal TAU-II
No Image Thrie-Beam (T)  Report 350  TL-3              Barrier Systems by Lindsay  Review Complete 
SCT01c
Universal TAU-II-R
No Image Thrie-Beam (T)  Report 350  TL-2              Barrier Systems by Lindsay  Review Complete 
SCT01d
Universal TAU-II-R
No Image Thrie-Beam (T)  Report 350  TL-3              Barrier Systems by Lindsay  Review Complete 
SCT02e
QuadGuard Elite System
No Image Thrie-Beam (T)  Report 350  TL-3              Energy Absorption Systems  Review Complete 
SCT02f
QuadGuard LMC System
No Image Thrie-Beam (T)  Report 350  TL-3              Energy Absorption Systems  Review Complete 
SCI13a
BEAT-SSCC, Driven Posts
No Image Independent (I)  Report 350  TL-3            26 [660mm] < H ≤ 30 [762mm]  Road Systems, Inc.  Review Complete 
SCI13b
BEAT-SSCC, Surface-Mounted Posts
No Image Independent (I)  Report 350  TL-3            26 [660mm] < H ≤ 30 [762mm]  Road Systems, Inc.  Review Complete 
SCT02b
Quadguard CZ System
No Image Thrie-Beam (T)  Report 350  TL-3              Energy Absorption Systems  Review Complete 
SCI23
X-Tenuator Crash Cushion
No image. Independent (I)  Report 350  TL-3            30 [762mm] < H ≤ 33 [838mm]  Barrier Systems by Lindsay  Review Complete 
SCI29
ArmorZone End Terminal TL-2
No Image Independent (I)  Report 350  TL-2            H > 33 [838mm]  Barrier Systems by Lindsay  Review Complete 
SCI07
Connecticut Impact Attenuation System
No image. Independent (I)  Report 350  TL-3            H > 33 [838mm]  Non-Proprietary  Review Complete 
SCI17d
SCI Smart Cushion - SCI100GM Impact Attenuator
No Image Independent (I)  MASH  TL-3  Redirective/Non-Gating  Yes  Yes  18' [5.49m] < L ≤ 25' [7.62m]  Multiple  30 [762mm] < H ≤ 33 [838mm]  Work Area Protection Corp.  Review Complete 
SCI10
N-E-A-T System
No Image Independent (I)  Report 350  TL-2            30 [762mm] < H ≤ 33 [838mm]  Energy Absorption Systems  Review Complete 
SCI11a
ABSORB 350
No Image Independent (I)  Report 350  TL-2            30 [762mm] < H ≤ 33 [838mm]  Barrier Systems by Lindsay  Review Complete 
SCI12
BEAT-BP
No Image Independent (I)  Report 350  TL-3            26 [660mm] < H ≤ 30 [762mm]  Road Systems, Inc.  Review Complete 
SCI15
EASI-Cell Cluster
No Image Independent (I)  Report 350  TL-1            H > 33 [838mm]  Energy Absorption Systems  Review Complete 
SCI16a
REACT 350
No Image Independent (I)  Report 350  TL-3            H > 33 [838mm]  Energy Absorption Systems  Review Complete 
SCI16b
REACT 350 (Wide)
No Image Independent (I)  Report 350  TL-3            H > 33 [838mm]  Energy Absorption Systems  Review Complete 
SCI17a
SCI100GM Impact Attenuator
No Image Independent (I)  Report 350  TL-3            30 [762mm] < H ≤ 33 [838mm]  Work Area Protection Corp.  Review Complete 
SCI17b
SCI70GM Impact Attenuator
No Image Independent (I)  Report 350  TL-2            30 [762mm] < H ≤ 33 [838mm]  Work Area Protection Corp.  Review Complete 
SCT01a
Universal TAU II
No Image Thrie-Beam (T)  Report 350  TL-2              Barrier Systems by Lindsay  Review Complete 
SCT02a
Quadguard System 24, 30, or 36 wide
No Image Thrie-Beam (T)  Report 350  TL-3              Energy Absorption Systems  Review Complete 
SCT02d
QuadGuard High Speed
No Image Thrie-Beam (T)  Report 350  TL-3              Energy Absorption Systems  Review Complete 
SCT02h
QuadGuard System (69 or 90 wide)
No image. Thrie-Beam (T)  Report 350  TL-3              Energy Absorption Systems  Review Complete 
SCI28
Compressor Crash Cushion
No image. Independent (I)  Report 350  TL-3              Traffix Devices, Inc.  No Drawing 
SCI22b
MASH Sentry Longitudinal Energy Dissipater (SLED)
No image. Independent (I)  MASH  TL-3              Traffix Devices, Inc.  No Drawing 
SCI30
Quadguard M10 Narrow Family TL-2
No image. Independent (I)  MASH  TL-2              Energy Absorption Systems  No Drawing 
SCI31
Quadguard M10 Wide Family TL-2
No image. Independent (I)  MASH  TL-2              Energy Absorption Systems  No Drawing 
SCI32
CrashGard Sand Barrel System
No Image Independent (I)  Report 350  TL-3              Plastic Safety Systems, Inc.  No Drawing 
SCI33
QuadGuard Elite 8 Bay M10
No image. Independent (I)  MASH  TL-3              Energy Absorption Systems  No Drawing 
SCI34
QuadGuard Elite 8 Bay Wide M10
No image. Independent (I)  MASH  TL-3              Energy Absorption Systems  No Drawing 
SCI35
QuadGuard Elite 4 Bay M10
No image. Independent (I)  MASH  TL-2              Energy Absorption Systems  No Drawing 
SCI36
QuadGuard Elite 4 Bay Wide M10
No image. Independent (I)  MASH  TL-2              Energy Absorption Systems  No Drawing 
SCI27
Quadguard M10 Wide Family
No image. Independent (I)  MASH  TL-3              Energy Absorption Systems  No Drawing 
SCI26b
Quadguard M10 Narrow Family
No image. Independent (I)  MASH  TL-3              Energy Absorption Systems  No Drawing 
SCI26a
Quadguard M10 Narrow Family
No image. Independent (I)  MASH  TL-3              Energy Absorption Systems  No Drawing 
SCI06b
Fitch Universal Module
No Image Independent (I)  Report 350  TL-3            Multiple  Energy Absorption Systems  No Drawing 
SCI09
ADIEM Energy Absorbing End Treatment
No image. Independent (I)  Report 350  TL-3            30 [762mm] < H ≤ 33 [838mm]  Trinity Highway Products  No Drawing 
SCI14
CushionWall II
No Image Independent (I)                  Energy Absorption Systems  No Drawing 
SCI16c
REACT 350 II
No image. Independent (I)  Report 350  TL-3              Energy Absorption Systems  No Drawing 
SCI18a
TRACC Crash Cushion Family (Narrow)
No image. Independent (I)  Report 350  TL-3              Trinity Highway Products  No Drawing 
SCI18b
TRACC Crash Cushion Family
No image. Independent (I)  Report 350  TL-3              Trinity Highway Products  No Drawing 
SCI19
Stop Gate
No Image Independent (I)  Report 350  TL-2              Energy Absorption Systems  No Drawing 
SCI20
Quest Crash Cushion
No image. Independent (I)  Report 350  TL-3              Energy Absorption Systems  No Drawing 
SCI21
HEART Crash Cushion
No image. Independent (I)  Report 350  TL-3              Trinity Highway Products  No Drawing 
SCI22a
SLED Sentry Longitudinal Energy Dissipater
No image. Independent (I)  Report 350  TL-2              Traffix Devices, Inc.  No Drawing 
SCI24
ACZ 350 TL-2 Crash Cushion
No image. Independent (I)  Report 350  TL-2              Energy Absorption Systems  No Drawing 
SCI25
Raptor Crash Cushion TL-1
No Image Independent (I)  Report 350  TL-1            H > 33 [838mm]  Barrier Systems by Lindsay  No Drawing 
SCT02g
QuadGuard 10 Degree Flare
No image. Thrie-Beam (T)  Report 350  TL-3              Energy Absorption Systems  No Drawing 
950 visitors have viewed this page since May 1, 2017.